The Eemax EX480 Series Six Electric Tankless Water Heater. This unit features
six powerful heating modules. Min. turn on 4 GPM max flow 13 GPM. Ideal for tepid
water for Eye/Face wash. (65°-90°) industrial/commercial applications.
Standard temp setting 100°-140° equipped with microprocessing thermostats.
Eemax EX480 Series Six Electric Tankless Water Heater Applications:
Eye/Face Combo "Tepid" Water
Commercial/Industrial
Capacity 4 to 13 GPM
Meets ANSI Z358.1 "tepid" water requirements for emergency
eye/face wash. Minimum flow 3 GPM
"Tepid" water, (60° to 95°) range
Eemax EX480 Series Six Electric Tankless Water Heater Features:
Unlimited On Demand Hot Water - no delay
Meets ANSI Z358.1 Tepid Water Requirements
Sophisticated Thermostatic Control continuously monitors outlet temperature
and adjust output for variations in flow and pressure.
Eliminate Costly Mixing Valves.
Easy Installation - only cold water supply needed - unit equipped with
1" NPT fitting
Reduced Installation Material Cost - no T&P relief needed (check
local codes)
Micro Processor Technology - accurately maintains outlet temperature
(+/- 1°F)
Splashproof Enclosure
Prevents legionella, mycrobacterial growth
Cut Energy Waste - flow switch activates heater only on demand (no standby
heat loss) - 99% efficient.
Compact Size
Field Serviceable Elements
Heater designed to fail to cold supply on electrical failure.
Eemax EX480 Series Six Electric Tankless Water Heater Specifications:
Dimensions - 32-3/32" x 20-3/32" x 6-3/32"
Weight - 42 lbs
KW - 48.0kW
Rise at 5 GPM - 65°F
Rise at 6 GPM - 54°F
Rise at 7.5 GPM - 43°F
Rise at 10 GPM - 32°F
Color - White
Element - Six replaceable cartridge elements plus two spares
Pipe-Fittings - 1" NPT fitting at bottom
208/120V requires: 3 lives, 1 ground (earth) (no neutral), 133A/phase,
Recommended Wire 2/0 AWG
480Y/277V requires: 3 lives, 1 neutral and 1 ground (earth), 58A/phase,
Recommended Wire 3 AWG
The voltage, amperage, and circuit breaker specifications must be met
for this heater to function. Please make sure all requirements are met before
purchasing this heater. Manufacturer's start up procedures must be observed.
Note: All of these Eemax units are custom made to order and as such are,
non-returnable and non-refundable. We urge you therefore to check your electrical
supply, making sure all criteria for operating your Eemax water heater are met,
especially that a neutral line is availablefor all 480Y/277V.
Click
Here For Specification
Volts/Amps Option:
208/120V requires: 3 lives, 1 ground (earth) (no neutral), 133A/phase,
Recommended Wire 2/0 AWG or
480Y/277V requires: 3 lives, 1 neutral and 1 ground (earth), 58A/phase, Recommended
Wire 3 AWG
Activation Turn On Options:
T6=Parellel turns on 4 GPM max flow 12 GPM
T24T=Turns on in stages, first stage 1 GPM, second stage 1.8 GPM, third stage
3.2 GPM, max. 6 GPM
Thermostatic Options:
S=Sanitation temperature setting 180°
FS=Factory set temperature setting (ambient 100°)
EF/Combo=Tepid water temperature setting emergency eye/face wash
Enclosure Option:
Nema 4= Waterproof enclosure 36"x30"x12"
Priced for EX480T6 S (208/120V requires: 3 lives, 1 ground (earth) (no neutral),
Parellel turn on, Sanitation setting 180°)